• Quelques infos sur ce monnayeur, merci à Seb59 pour le récapitulatif de cette documentation.

    FAQ Cashflow 330

    Service manual programmation Cashflow 330

    Un extrait de la doc pour reprogrammer ce monnayeur :

    How do I inhibit an individual coin. ?

    1) Cycle power to the acceptor.
    2) Adjust the switch positions on the 4 bit DIL switch as follows:
    1=ON
    2=ON
    3=OFF
    4=ON
    3) Press the reject lever within a 4 minute time out period.
    4) Insert coins to be inhibited until they are accepted.
    5) Press the reject lever to return to operational mode.
    6) Remove power.
    7) Return all switches to the off position..
    8 ) Restore power to the acceptor.

    How do I enable an individual coin. ?

    1) Cycle power to the acceptor.
    2) Adjust the switch positions on the 4 bit DIL switch as follows:
    1=ON
    2=ON
    3=OFF
    4=OFF
    3) Press the reject lever within a 4 minute time out period.
    4) Insert coins to be enabled until they are accepted.
    5) Press the reject lever to return to operational mode.
    6) Remove power.
    7) Return all switches to the off position..
    8 ) Restore power to the acceptor.

    Je viens de tester cette manipulation avec succès, il suffit de suivre les instructions et la nouvelle pièce ou jeton sera dorénavant accepté.

    Posted by nicolas @ 12:08 pm

3 Comments to Monnayeur Cashflow 330

  • Je ne comprend pas cette étape:

    -Press the reject lever within a 4 minute time out period.

    On n’a 4 minutes pour faire la manip’ ou bien il faut attendre 4 minutes?

  • Il faut que la pièce ou le jeton soit déja enregistré dans le monnayeur (via un programmateur).
    La manip permet alors de réactiver ou désactiver la pièce en question.